1 |
Defect Report Number: 8632-1/040
|
|
2 |
Submitter: Henderson
|
|
3 |
Addressed to: JTC1/SC 24/WG 6 Rapporteur Group on ISO/IEC 8632, CGM
|
|
4 |
WG secretariat: NNI
|
|
5 |
Date Circulated by WG secretariat: 1 January 1995
|
|
6 |
Deadline on response from editor: : 1 April 1995
|
|
7 |
Defect Report concerning IS 8632:1992 Computer Graphics: Metafile for the storage and transfer of picture description information (CGM) Part 1, Functionalspecification.
|
|
8 |
Qualifier (e.g. error, omission, clarification required): Correction.
|
|
9 |
References in document (e.g. page, clause, figure and/or table numbers):p.21, last paragraph of 4.3.4.5
|
|
10 |
Nature of defect (complete, concise explanation of the perceived problem):
The CHARACTER CODING ANNOUNCER has no effect on the coding of type SF parameters, contrary to the implication in this paragraph. The list of invocation and designation codes is not all-inclusive. For example, LS2 and LS3 (the locking shifts) are omitted and are valid 7-bit controls.
|
|
11 |
Solution proposed by the submitter (optional):
Terminate the paragraph after the word "permitted", and delete the remainder. Delete "(SI, SO, ESC, SS2, and SS3)".
|
|
12 |
Editor's response (any material proposed for processing as a technical corrigendum to, an amendment to, or a commentary on the International Standard or DIS final text is attached separately to this completed report):
Amend the standard as proposed above.
|